Cisco Cisco Packet Data Interworking Function (PDIF)
PDSN Service Configuration Mode Commands
threshold a11-rrp-failure ▀
Command Line Interface Reference, StarOS Release 16 ▄
7777
threshold a11-rrp-failure
Sets an alarm or alert based on the number of A11 Registration Response failures for the PDSN service.
Product
PDSN
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration > Context Configuration > PDSN Service Configuration
configure > context context_name > pdsn-service service_name
Entering the above command sequence results in the following prompt:
[context_name]host_name(config-pdsn-service)#
Syntax
threshold a11-rrp-failure high_thresh [ clear low_thresh ]
no threshold a11-rrp-failure
no
Deletes the alert or alarm.
high_thresh
Default: 0
The high threshold number of A11 Registration Response failures that must be met or exceeded within the
polling interval to generate an alert or alarm. It can be configured to any integer value between 0 and 100000.
The high threshold number of A11 Registration Response failures that must be met or exceeded within the
polling interval to generate an alert or alarm. It can be configured to any integer value between 0 and 100000.
clear
low_thresh
Default:0
The low threshold number of A11 Registration Response failures that must be met or exceeded within the
polling interval to clear an alert or alarm. It can be configured to any integer value between 0 and 100000.
The low threshold number of A11 Registration Response failures that must be met or exceeded within the
polling interval to clear an alert or alarm. It can be configured to any integer value between 0 and 100000.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
Use this command to set an alert or an alarm when the number of A11 Registration Response failures is equal
to or greater than a specified number.
Alerts or alarms are triggered for the number of A11 Registration Response failures based on the following
rules:
to or greater than a specified number.
Alerts or alarms are triggered for the number of A11 Registration Response failures based on the following
rules:
Enter condition: Actual number of A11 Registration Response failures > High Threshold
Clear condition: Actual number of A11 Registration Response failures £ Low Threshold
Example