Cisco Cisco Packet Data Interworking Function (PDIF)
System Changes in Release 16
▀ System and Platform Enhancements for 16.1
▄ Release Change Reference, StarOS Release 16
618
fabric egress drop-threshold enable count number interval-secs seconds
end
Notes:
count number specifies the maximum number of egress traffic packets that can be dropped before a syslog event
message is generated. The count is specified as an integer from 10 through 5000.
interval-secs seconds specifies the time interval (window) within which the maximum egress packet drop count
can be exceeded. The interval is specified in seconds as an integer from 30 through 600.
When the threshold is exceed, the syslog event message is generated once, until the condition clears. Only then
will it be generated again.
By default this feature is disabled.
CSCuo91363 - Non-Redundant MIO Failure recovery action upon initialization
failure
Applicable Products: All (ASR 5500)
Feature Changes
Initialization of MIOs on Switchover
During switchover from MIO5 to MIO6 initialization failed when it took too long due to control plane issues, resulting
in a forced restart of the processes. Control plane issues in the chassis remained after restart. StarOS also came up with
an incorrect boot configuration file after restart
in a forced restart of the processes. Control plane issues in the chassis remained after restart. StarOS also came up with
an incorrect boot configuration file after restart
Previous Behavior: Failed switchover attempt caused forced restart of processes.
New Behavior: A StarOS restart now reboots both MIOs with improved handling of local card restart.