Cisco Cisco Packet Data Interworking Function (PDIF) Prospecto
Global Configuration Mode Commands (threshold ppp - url-blacklisting)
▀ threshold ppp-setup-fail-rate
▄ Cisco ASR 5x00 Command Line Interface Reference
5638
threshold ppp-setup-fail-rate
Configures alarm or alert thresholds for the percentage of point-to-point protocol (PPP) setup failures.
Product
PDSN
GGSN
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration
configure
Entering the above command sequence results in the following prompt:
[local]host_name(config)#
Syntax
threshold ppp-setup-fail-rate high_thresh [ clear low_thresh ]
high_thresh
Default: 0
Specifies the high threshold rate percentage for PPP setup failures experienced by the system that must be
met or exceeded within the polling interval to generate an alert or alarm.
Specifies the high threshold rate percentage for PPP setup failures experienced by the system that must be
met or exceeded within the polling interval to generate an alert or alarm.
high_thresh
is an integer from 0 through 100. A value of 0 disables the threshold.
clear
low_thresh
Default: 0
Specifies the low threshold rate percentage for PPP setup failures experienced by the system that maintains a
previously generated alarm condition. If the number of setup failures falls beneath the low threshold within
the polling interval, a clear alarm will be generated.
Specifies the low threshold rate percentage for PPP setup failures experienced by the system that maintains a
previously generated alarm condition. If the number of setup failures falls beneath the low threshold within
the polling interval, a clear alarm will be generated.
low_thresh
is an integer from 0 through 100. A value of 0 disables the threshold.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
PPP setup failure rate thresholds generate alerts or alarms based on the rate of call setup failures experienced
by the system during the specified polling interval. The failure rate is the percentage of failures as determined
by number of PPP setup failures divided by the total number of PPP sessions initiated.
Alerts or alarms are triggered for PPP setup failure rates based on the following rules:
by the system during the specified polling interval. The failure rate is the percentage of failures as determined
by number of PPP setup failures divided by the total number of PPP sessions initiated.
Alerts or alarms are triggered for PPP setup failure rates based on the following rules:
Enter condition: Actual number of call setup failures is greater than or equal to the high threshold.
Clear condition: Actual number of call setup failures is less than the low threshold.
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end
of the polling interval.