Cisco Cisco Packet Data Interworking Function (PDIF) Prospecto
PDSN Service Configuration Mode Commands
threshold init-rrq-rcvd-rate ▀
Cisco ASR 5x00 Command Line Interface Reference ▄
7587
threshold init-rrq-rcvd-rate
Sets an alarm or alert based on the average number of calls setup per second for the context.
Product
PDSN
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration > Context Configuration > PDSN Service Configuration
configure > context context_name > pdsn-service service_name
Entering the above command sequence results in the following prompt:
[context_name]host_name(config-pdsn-service)#
Syntax
threshold init-rrq-rcvd-rate high_thresh [ clear low_thresh ]
no threshold init-rrq-rcvd-rate
no
Deletes the alert or alarm.
high_thresh
Default: 0
The high threshold average number of calls setup per second must be met or exceeded within the polling
interval to generate an alert or alarm. It can be configured to any integer value between
The high threshold average number of calls setup per second must be met or exceeded within the polling
interval to generate an alert or alarm. It can be configured to any integer value between
0
and
1000000
.
clear
low_thresh
Default:0
The low threshold average number of calls setup per second that must be met or exceeded within the polling
interval to clear an alert or alarm. It can be configured to any integer value between
The low threshold average number of calls setup per second that must be met or exceeded within the polling
interval to clear an alert or alarm. It can be configured to any integer value between
0
and
1000000
.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
Use this command to set an alert or an alarm when the average number of calls setup per second is equal to or
greater than a specified number of calls per second.
Alerts or alarms are triggered for the number of calls setup per second based on the following rules:
greater than a specified number of calls per second.
Alerts or alarms are triggered for the number of calls setup per second based on the following rules:
Enter condition: Actual number of calls setup per second > High Threshold
Clear condition: Actual number of calls setup per second £ Low Threshold
Example