Cisco Cisco Packet Data Interworking Function (PDIF)
Call Setup Thresholds
▀ PPP Setup Failure Rate Thresholds
▄ Thresholding Configuration Guide, StarOS Release 17
38
PPP Setup Failure Rate Thresholds
PPP setup failure rate thresholds generate alerts or alarms based on the rate of call setup failures experienced by the
system during the specified polling interval. The failure rate is the percentage of failures as determined by number of
PPP setup failures divided by the total number of PPP sessions initiated.
system during the specified polling interval. The failure rate is the percentage of failures as determined by number of
PPP setup failures divided by the total number of PPP sessions initiated.
Alerts or alarms are triggered for PPP setup failure rates based on the following rules:
Enter condition: Actual number of call setup failures > or = High Threshold
Clear condition: Actual number of call setup failures < Low Threshold
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end of the
polling interval.
polling interval.
Configuring PPP Setup Failure Rate Thresholds
Use the following example for configuring PPP setup failure rate thresholding:
configure
threshold ppp-setup-fail-rate <high_thresh> [ clear <low_thresh> ]
threshold poll ppp-setup-fail-rate interval <time>
threshold monitoring call-setup
end