Cisco Cisco Packet Data Gateway (PDG)

Descargar
Página de 360
Introduction to VPC-VSM   
▀  Diagnostics and Monitoring 
 
 
▄  VPC-VSM System Administration Guide, StarOS Release 19 
24 
   
Diagnostics and Monitoring 
Because VPC-VSM runs within a VM, no hardware diagnostics or monitoring are provided. Retrieval of hardware 
sensor data (temperature, voltage, memory errors) are accomplished via the IOS-XR monitoring systems. 
VPC-VSM monitors and exports vCPU, vRAM, and vNIC usage through existing mechanisms including CLI show 
commands, bulkstats and MIB traps. However, an operator may find that monitoring physical CPU, RAM, and NIC 
values in the hypervisor is more useful. 
Because vNICs have a variable maximum throughput, counters and bulkstats that export utilization as a percentage of 
throughput may have little value. Absolute values (bps) should be obtained from VPC-VSM where possible; physical 
infrastructure utilization should be obtained from the hypervisor or IOS-XR via the ASR 9000 route processor (RP).