Cisco Cisco WAP200E Wireless-G Exterior Access Point - PoE Manual De Mantenimiento
6
Installation
Wireless-G Exterior Access Point with Power Over Ethernet
Chapter 4
Chapter 4:
Installation
Installation
Overview
This chapter explains how to mount and connect the
Access Point.
Access Point.
Depending on your application, you might want to set
up the IP address of the device first before mounting
the device. Refer to “Chapter 5: Quick Configuration
Overview”.
up the IP address of the device first before mounting
the device. Refer to “Chapter 5: Quick Configuration
Overview”.
Personal Installation
This product should be installed by a qualified installation
professional with RF and related rule knowledge. General
users should not attempt to install this product or modify
the settings.
professional with RF and related rule knowledge. General
users should not attempt to install this product or modify
the settings.
Installation Location
The product should be installed in a location where the
radiating antenna is at least 20 cm from anyone under
normal operating conditions. This is required to meet
regulatory RF exposure requirements.
radiating antenna is at least 20 cm from anyone under
normal operating conditions. This is required to meet
regulatory RF exposure requirements.
External Antenna
Use only antennas approved by Linksys. Antennas that have
not been approved by Linksys may produce unwanted
spurious or excessive RF transmitting power, this may lead
to violation of FCC limitations and is prohibited.
not been approved by Linksys may produce unwanted
spurious or excessive RF transmitting power, this may lead
to violation of FCC limitations and is prohibited.
Installation Procedure
Follow the Hardware Installation instructions for details
on installing this product.
on installing this product.
WARNING:
Please carefully select the
installation position and make sure that the
final output power does not exceed the limit
defined in US Rule CFR 47 Part 15, section
15.247 and 15.407. Violation of the rule could
lead to serious federal penalties.
final output power does not exceed the limit
defined in US Rule CFR 47 Part 15, section
15.247 and 15.407. Violation of the rule could
lead to serious federal penalties.
Hardware Installation
Locate an optimum location on a wall for the Access
1.
Point. Refer to the antenna pattern in “Chapter 3:
Product Overview” to adjust the angle of the Access
Point for your application.
Product Overview” to adjust the angle of the Access
Point for your application.
Using the mounting plate as a template, mark the
2.
locations of the two wall-mount slots that are on the
bottom of the mounting plate. Then, install a screw
into each location.
bottom of the mounting plate. Then, install a screw
into each location.
Mark the Locations of the Two Wall-Mount Slots
Use four screws (included with the Access Point) to
3.
attach the mounting plate to the back panel of the
Access Point.
Access Point.
Attach the Mounting Plate
Connect the included Category 5e Ethernet network
4.
cable to the Ethernet network port of the Access Point.