Cisco Cisco Aironet 1200 Access Point Notas de publicación

Descargar
Página de 22
 
6
Release Notes for Cisco Aironet Access Points for Cisco IOS Release 12.3(8)JEB
OL-11737-01
  New Features
New Features
This release contains one new feature: 
WDS-only Mode—You can configure an access point running Cisco IOS Release 12.3(8) JEB to 
function in WDS-only mode. In this mode the access point functions only as a WDS, providing 
domain services to other access points and clients.
Installation Notes
This section contains information you should keep in mind when installing Cisco Aironet autonomous 
access points.
Installation in Environmental Air Space
This section provides information on installing 1100 and 1200 series access points in environmental air 
space, such as above suspended ceilings.
Cisco Aironet 1100, and 1200 series access points provide adequate fire resistance and low 
smoke-producing characteristics suitable for operation in a building's environmental air space, such as 
above suspended ceilings, in accordance with Section 300-22(C) of the National Electrical Code (NEC) 
and Sections 2-128, 12-010(3) and 12-100 of the Canadian Electrical Code, Part 1, C22.1.
Caution
The power injector does not provide fire resistance and low smoke-producing characteristics and is not 
intended for use in extremely high or low temperatures or in environmental air spaces such as above 
suspended ceilings.
Note
If you plan to mount a 1200 series access point with a 5-GHz radio in an area subject to environmental 
air space, Cisco recommends that you mount the access point horizontally so that its antennas point 
down. Doing so ensures that the access point complies with regulatory requirements for environmental 
air space with the 5-GHz radio installed. 
Power Considerations
This section describes issues you should consider before applying power to an access point.
Caution
The operational voltage range for 1100 series access points is 35 to 57 VDC, and the nominal voltage is 
48 VDC. Voltage higher than 60 VDC can damage the equipment.
Caution
The nominal voltage for 1200 series access points is 48 VDC, and the access point is operational up to 
60 VDC. Voltage higher than 60 VDC can damage the equipment.