Unpacking and Installing the Cisco ONS 15216 Five-Component Bay Assembly (15216-TERM-BAY)
78-15972-01
  GMT-TPA Fuse and Alarm Panel
Warning
If you use redundant power leads to power the ONS 15216, disconnecting one lead will not remove 
power from the node.
Caution
Always use the supplied ESD wristband when working with a powered ONS 15216. Plug the wristband 
cable into the ESD jack located on the lower-right outside edge of the shelf assembly.
Central Office Ground to Bay Wire Ground
Connect the CO ground to the bay wire ground according to local site practice.
Note
The bay assembly ground must be attached to the common central office (CO) ground via an H TAP 
compression connector.
 
FAP Output and Input Power
Route and connect output and input power according to local site practice. 
 through 
show output and input lugs and wiring and 
 and 
 list lug wiring positions.
Note
CO power from the BDFB to the bay assembly must be a direct feed from a single breaker (one breaker 
for return, and one breaker for -48VDC) at the BDFB to the input connection of the bay assembly. The 
size or gauge of the power wire feed must be calculated by the distance from the BDFB to the FAP.