Cisco Cisco ONS 15216 (EDFA3) Metropolitan Regional DWDM System Guía De Instalación

Descargar
Página de 28
Before installing the fiber-optic cable, always perform the cleaning procedure for cable connectors described
in the following section. Whenever possible, inspect each connector before connecting it to the optical
mating adapter on the front panel.
Note
The LC optical mating adapter on the faceplate of the device is less likely to get dirty if it is capped when
not in use. On some devices, the optical mating adapter has a shutter. The shutter automatically closes
when the LC/UPC connector is disconnected. This prevents entry of dirt.
The procedure for a thorough cleaning of these adapters is complicated. Use a commercially available
cleaning kit and closely follow the instructions included with the kit.
Note
Customer-supplied Cleaning Materials
The Type A fiber optic connector cleaners (for example, CLETOP reel) are recommended to clean the cable connectors, but are not
supplied with the device.
If properly maintained (only used with clean, defect-free fiber connectors and capped when not in use), the mating adapter would
not require cleaning. However, if you suspect the adapter is dirty, clean it by using the CLETOP stick swab.
For multifiber cable assemblies, use specific cleaning tools or materials designed for the assembly type.
Note
Cleaning the Optical Mating Adapter
Procedure
Step 1
Read the cartridge cleaning instructions (provided by the manufacturer) to insert the cartridge cleaning tip into the optical
mating adapter.
Step 2
Slide the lever on the cartridge to swipe the mating surface.
Always keep unused adapter ports and fiber connectors capped with a clean dust cap. The optical mating adapters
that have shutter need not be capped.
Note
Cleaning Fiber-Optic Cable Connectors
The tools required to clean fiber connectors are:
• Inspection microscope
• Type A Fiber Optic Connector Cleaner (CLETOP reel)
• Optical swab
19