Cisco Cisco ONS 15216 (EDFA3) Metropolitan Regional DWDM System Hoja De Datos
Cisco Systems, Inc.
All contents are Copyright © 1992–2005 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 3 of 5
Table 1.
Ordering Information
Product Number
Product Description
15216-SC-CL=
C+L-Band Splitter/Combiner Module
To check prices and lead times, and to order products, go to:
http://www.cisco.com/en/US/ordering/index.shtml
.
PRODUCT SPECIFICATIONS
Tables 2 and 3 list technical and environmental specifications for the Cisco ONS 15216 C+L-Band Splitter/Combiner Module. Table 4 provides
port information.
Table 2.
Technical Specifications
Parameter
Condition
Note
Min
Max
Units
(C + OSC) Band Wavelength
Range
Range
(–0.5 dB Bandwidth)
LINE-RX
→
SPL-TXC
CPL-RXC
→
LINE-TX
All Standard Operating Procedure
(SOP) and within whole operating
temperature range.
(SOP) and within whole operating
temperature range.
1500 to
1562
1562
nm
L-Band Wavelength Range
(–0.5 dB Bandwidth)
LINE-RX
→
SPL-TXL
CPL-RXL
→
LINE-TX
All SOP and within whole
operating temperature range.
operating temperature range.
1570 to
1605
1605
nm
Insertion Loss
1
(C+OSC) Band
LINE-RX
→
SPL-TXC
CPL-RXC
→
LINE-TX
0.5
1
dB
Insertion Loss
2
L-Band
LINE-RX
→
SPL-TXL
CPL-RXL
→
LINE-TX
All SOP and within whole
operating temperature range,
including 2 connectors.
operating temperature range,
including 2 connectors.
0.3
0.8
dB
MON-LINE
with respect to LINE-RX
24
27
dB
MON Loss
3
MON-CPL
with respect to LINE-TX
All SOP and within whole
operating temperature range,
including 2 connectors.
operating temperature range,
including 2 connectors.
27
30
dB
LINE-RX
→
SPL-TXC
25
dB
Isolation
LINE-RX
→
SPL-TXL
All SOP and within whole
operating temperature range.
operating temperature range.
12
dB
C-Band + OSC
Channels Band Ripple
LINE-RX
→
SPL-TXC
CPL-RXC
→
LINE-TX
All SOP and within whole
operating temperature range.
operating temperature range.
0.3
dB
L-Band
Channels Band Ripple
LINE-RX
→
SPL-TXL
CPL-RXL
→
LINE-TX
All SOP and within whole
operating temperature range.
operating temperature range.
0.15
dB
Chromatic Dispersion
Each optical path
All SOP and within whole
operating temperature range.
operating temperature range.
–20
+20
ps/nm
Polarization Mode Dispersion
(PMD)
(PMD)
Each optical path
Within whole operating
temperature range.
temperature range.
0.1
ps
Polarization Dependent Loss (PDL)
Each optical path
Within whole operating
temperature range.
temperature range.
0.1
dB
Return Loss
All optical ports.
40
dB
Directivity
All SOP and within whole
operating temperature range.
operating temperature range.
40
dB
Maximum Power Handling
Within whole operating
temperature range.
temperature range.
500
mW
1 All the Insertion Loss values have to be measured as the maximum insertion loss inside the Total (C + OSC) Optical Bandwidth.
2 All the Insertion Loss values have to be measured as the maximum insertion loss inside the Total L Optical Bandwidth.
3 All the Insertion Loss values have to be measured as the maximum insertion loss inside the Total Optical Bandwidth (C + OSC band and L band).