Cisco Cisco ONS 15216 (EDFA3) Metropolitan Regional DWDM System Hoja De Datos

Descargar
Página de 6
 
 
Cisco Systems, Inc.  
All contents are Copyright © 1992–2005 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement. 
Page 3 of 5 
 
 
Table 1. 
Ordering Information  
Product Number 
Product Description 
15216-SC-CL= 
C+L-Band Splitter/Combiner Module 
To check prices and lead times, and to order products, go to: 
http://www.cisco.com/en/US/ordering/index.shtml
PRODUCT SPECIFICATIONS 
Tables 2 and 3 list technical and environmental specifications for the Cisco ONS 15216 C+L-Band Splitter/Combiner Module. Table 4 provides 
port information. 
Table 2. 
Technical Specifications 
Parameter 
Condition 
Note 
Min 
Max 
Units 
(C + OSC) Band Wavelength 
Range 
(–0.5 dB Bandwidth) 
LINE-RX 
 SPL-TXC 
CPL-RXC 
 LINE-TX 
All Standard Operating Procedure 
(SOP) and within whole operating 
temperature range. 
1500 to 
1562 
  
nm 
L-Band Wavelength Range 
(–0.5 dB Bandwidth) 
LINE-RX 
 SPL-TXL 
CPL-RXL 
 LINE-TX 
All SOP and within whole 
operating temperature range. 
1570 to 
1605 
  
nm 
Insertion Loss
1
 (C+OSC) Band 
LINE-RX 
 SPL-TXC 
CPL-RXC 
 LINE-TX 
0.5 
dB 
Insertion Loss
2
 L-Band 
LINE-RX 
 SPL-TXL 
CPL-RXL 
 LINE-TX 
All SOP and within whole 
operating temperature range, 
including 2 connectors. 
0.3 
0.8 
dB 
MON-LINE 
with respect to LINE-RX 
24 
27 
dB 
MON Loss
3
 
MON-CPL 
with respect to LINE-TX 
All SOP and within whole 
operating temperature range, 
including 2 connectors. 
27 
30 
dB 
LINE-RX 
 SPL-TXC 
25 
  
dB 
Isolation 
LINE-RX 
 SPL-TXL 
All SOP and within whole 
operating temperature range. 
12 
  
dB 
C-Band + OSC  
Channels Band Ripple 
LINE-RX 
 SPL-TXC 
CPL-RXC 
 LINE-TX 
All SOP and within whole 
operating temperature range. 
  
0.3 
dB 
L-Band  
Channels Band Ripple 
LINE-RX 
 SPL-TXL 
CPL-RXL 
 LINE-TX 
All SOP and within whole 
operating temperature range. 
  
0.15 
dB 
Chromatic Dispersion 
Each optical path 
All SOP and within whole 
operating temperature range. 
–20 
+20 
ps/nm 
Polarization Mode Dispersion 
(PMD)  
Each optical path 
Within whole operating 
temperature range. 
  
0.1 
ps 
Polarization Dependent Loss (PDL) 
Each optical path 
Within whole operating 
temperature range. 
  
0.1 
dB 
Return Loss 
  
All optical ports. 
40 
  
dB 
Directivity 
  
All SOP and within whole 
operating temperature range. 
40 
  
dB 
Maximum Power Handling 
  
Within whole operating 
temperature range. 
500 
  
mW 
1 All the Insertion Loss values have to be measured as the maximum insertion loss inside the Total (C + OSC) Optical Bandwidth. 
2 All the Insertion Loss values have to be measured as the maximum insertion loss inside the Total L Optical Bandwidth. 