Cisco Cisco ONS 15454 M12 Multiservice Transport Platform (MSTP) Notas de publicación
![Cisco](https://files.manualsbrain.com/attachments/7380d0050044647c30f5c24bbbf5d0c0b6d9bb84/common/fit/150/50/faa183d287233c52228cfea3dbc2a127fe780f60564fcb0955d9c3d1cd23/brand_logo.png)
44
Release Notes for Cisco ONS 15454 Release 7.2.2
OL-12443-01
New Features and Functionality
Step 4
Check for switching (Manual, Forced, Fiber pull etc.) of circuits going on STS1, STS48, STS49, STS96
on the span card.
on the span card.
Step 5
All the switches were within 20 ms.
Step 6
Check the same in 4F BLSR setup as well.
For 4F checked for circuit going on STS1, STS48, STS192, and STS145.
The problem is not observed. Hence, the issue is resolved.
Interoperability
CSCse40661
Variables not visible to the user are uninitialized. The variables are not used so there is no bad behavior
observed. However, these variables interfere with our ability to debug ospf-related issues. These
variables are uninitialized on non-OSC links. The variables are isOptLinkEast and optRingID. They take
on random values for non-OSC links. No work-around is available. There is no visible or adverse effect
to this issue. This issue is resolved in Release 6.2.2.
observed. However, these variables interfere with our ability to debug ospf-related issues. These
variables are uninitialized on non-OSC links. The variables are isOptLinkEast and optRingID. They take
on random values for non-OSC links. No work-around is available. There is no visible or adverse effect
to this issue. This issue is resolved in Release 6.2.2.
TL1
CSCsh04184
When a cross connect/circuit is created through CTC with E-Series card as one end, the output of the
command RTRV-CRS: SLOT-ALL: a; from TL1 does not contain the E-Series end's AID. This bug is
found in 7.0. It has been fixed in 7.0.4, 7.2.2, 8.0, 8.0.1
command RTRV-CRS: SLOT-ALL: a; from TL1 does not contain the E-Series end's AID. This bug is
found in 7.0. It has been fixed in 7.0.4, 7.2.2, 8.0, 8.0.1
CSCsc62784
The Calibration Tilt is not properly changed using the TL1 interface. The reference tilt is changed
instead. This issue can be seen when you try to change the CALTILT parameter on amplifier cards using
the ED-OTS command. To avoid this issue, use CTC. This issue is resolved in Release 7.2.
instead. This issue can be seen when you try to change the CALTILT parameter on amplifier cards using
the ED-OTS command. To avoid this issue, use CTC. This issue is resolved in Release 7.2.
New Features and Functionality
This section highlights new features and functionality for Release 7.2. For detailed documentation of
each of these features, consult the user documentation.
each of these features, consult the user documentation.