Cisco Cisco ONS 15454 M6 Multiservice Transport Platform (MSTP)

Descargar
Página de 45
Status
OID
Name
No. Column
{1.3.6.1.2.1.16.1.1.1.19}
etherStatsPkts1024to1518Octets
29
{1.3.6.1.2.1.16.1.1.1.6}
EtherStatsBroadcastPkts
30
{1.3.6.1.2.1.16.1.1.1.7}
EtherStatsMulticastPkts
31
{1.3.6.1.2.1.16.1.1.1.10}
EtherStatsOversizePkts
32
{1.3.6.1.2.1.16.1.1.1.12}
EtherStatsJabbers
33
{1.3.6.1.2.1.16.1.1.1.4}
EtherStatsOctets
34
{1.3.6.1.2.1.16.1.1.1.13}
EtherStatsCollisions
35
{1.3.6.1.2.1.16.1.1.1.8}
EtherStatsCollisions
36
Unsupported in E100/E1000
and G1000
{1.3.6.1.2.1.16.1.1.1.3}
EtherStatsDropEvents
37
Get Requests and GetNext Requests
Get requests and getNext requests for the etherStatsMulticastPkts and etherStatsBroadcastPkts columns return a value of zero because
the variables are not supported by ONS 15454 Ethernet cards.
Row Deletion in alarmTable
To delete a row from the table, the SetRequest PDU should contain an alarmStatus value of 4 (invalid). A deleted row can be recreated.
Entries in this table are preserved if the SNMP agent is restarted.
Event RMON Group
The Event group controls event generation and notification. It consists of two tables: the eventTable, which is a read-only list of
events to be generated, and the logTable, which is a writable set of data describing a logged event. The ONS 15454 implements the
logTable as specified in RFC 2819.
Event Table
The eventTable is read-only and not provisionable. The table contains one row for rising alarms and another for falling ones. This
table has the following restrictions:
• The eventType is always log-and-trap (4).
• The eventCommunity value is always a zero-length string, indicating that this event causes the trap to be despatched to all
provisioned destinations.
• The eventOwner column value is always “monitor.”
41