DLP-G95 Set Up External or Line Timing
This task defines the ONS 15454 timing source (external or
line).
Purpose
None
Tools/Equipment
"DLP-G46 Log into CTC" task in
document.
Prerequisite Procedures
Required
Required/As Needed
Onsite or remote
Onsite/Remote
Provisioning or higher
Security Level
Procedure
Step 1
In node view (single-node mode) or shelf view (multishelf mode), click the Provisioning > Timing > General tabs.
Step 2
In the General Timing area, complete the following information:
• Timing Mode-Choose External if the ONS 15454 derives its timing from a BITS source wired to the backplane pins
(ANSI) or a MIC-C/T/P front-mount electrical connection (FMEC) (ETSI); choose Line if timing is derived from
an OSC-CSM or OSCM card that is optically connected to the timing node. A third option, Mixed, allows you to set
both external and line timing references. Because Mixed timing might cause timing loops, we do not recommend its
use. Use this mode with care.
In ONS 15454 M6 the BITS is connected to ECU or ECU2 BITS Connectors. Refer to "DLP-G296 Install
Timing Wires on ONS 15454 M6 - ANSI" in the Cisco ONS 15454 Hardware Installation Guide . In ONS
15454 M2 he BITS is connected to BITS connectors on the Power Unit.
Note
• SSM Message Set-Choose the Generation 2 synchronization status messaging (SSM) option. See the section
for more information about SSM, including definitions of the SONET
timing levels.
Generation 1 is used only by SONET or SDH ONS 15454 nodes that are connected to equipment that does
not support Generation 2.
Note
• Quality of RES-Sets the timing quality for the user-defined, reserved (RES) S1 byte if your timing sources supports
RES. Most timing sources do not use RES. If it does not support RES, choose RES=DUS (do not use for timing
reference). Qualities are displayed in descending quality order as ranges. For example, in Generation 1 SSM,
ST3<RES<ST2 means that the timing reference RES is higher than a Stratum 3 (ST3) and lower than a Stratum 2
(ST2)
• Revertive-Select this check box if you want the ONS 15454 to revert to a primary reference source after the conditions
that caused it to switch to a secondary timing reference are corrected.
• Reversion Time-If Revertive is checked, choose the amount of time that the ONS 15454 will wait before reverting
to its primary timing source. Five minutes is the default.