Cisco Cisco Prime Central 1.3 Guía De Instalación

Descargar
Página de 83
Verifying the Silent Installation
Procedure
Step 1
Open a web browser and log in to the Prime Central portal at https://server-hostname:https-port-number, where:
• server-hostname is the hostname of the newly installed Prime Central server.
• https-port-number is the SSL port number that was configured during installation.
Step 2
Enter the username centraladmin and the admin user password that you specified for the silent installation.
If you cannot log in to the Prime Central portal, check the silent installation log files in the installation-directory/install/logs/
folder. If the installation failed, the log files contain errors and exceptions that you can use for troubleshooting.
Installing Prime Central Fault Management
Installing the Prime Central Fault Management component—which has its own installation DVD and installation binary—is a two-part
process:
1
Prepare the server for installation.
2
Install the Prime Central Fault Management component.
During the installation, the variables that you define must adhere to the constraints described in
Note
Preparing the Server for Installation
Before you install the Prime Central Fault Management component, you must first connect to the server and, if using X server, verify
the display settings.
Procedure
Step 1
Use one of the following options to connect to the server where you want to install Prime Central Fault Management:
• VNC (recommended)—See
• X server—For this option, Reflection X is recommended. See
.
Step 2
As the root user, launch a terminal on the server where you want to install Prime Central Fault Management. The C shell
(csh) is recommended. To start the C shell, enter:
/bin/csh
If you are using X server, continue to the next step.