Cisco Cisco MCS 7845-I3 Hoja De Datos

Descargar
Página de 5
 
 
Data Sheet 
© 2010-2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 3 of 5 
Component 
Value 
System management ports 
Shared Ethernet port 
Eight PCIe non-hot plug slots 
Height: 1.75 in. (1RU) 
Height: 43 mm 
Width: 
  17.32 in. 
Width: 
  440 mm 
Dimensions (H x W x D) 
Depth: 
  Overall: 22 in. 
Depth: 
  Overall: 559 mm 
Weight (maximum) 
28 lb 
12.7 kg 
Rated line voltage: 100-127 VAC; 50 or 60 Hz 
Input current (amps) 
0.65 (idle) 
1.74 (maximum measured) 
6.0 (system rated) 
40 (peak inrush current; 4 ms) 
Leakage current (mA) 
0.47 (idle; maximum measured; system rated) 
Power (watts) 
76 (idle) 
196 (maximum measured) 
351 (system rated) 
VA rating (VA) 
78 (idle) 
201 (maximum measured) 
351 (system rated) 
BTU rating (BTU/hr) 
259 (idle) 
669 (maximum measured) 
2047 (system rated) 
Rated line voltage: 200-240 VAC; 50 or 60 Hz 
Input current (amps) 
0.37 (idle) 
0.92 (maximum measured) 
3.0 (system rated) 
40 (peak inrush current; 4 ms) 
Leakage current (mA) 
0.47 (idle; maximum measured; system rated) 
Power (watts) 
75 (idle) 
192 (maximum measured) 
351 (system rated) 
VA rating (VA) 
77 (idle) 
197 (maximum measured) 
351 (system rated) 
Input requirements
1
 
BTU rating (BTU/hr) 
256 (idle) 
656 (maximum measured) 
2047 (system rated) 
Power supply output power 
Rated steady-state power 
351W 
Operating 
50 to 95°F (10 to 35°C) 
at 0-3000 ft (0-914.4m) 
with an altitude de-rating of 
1.4°F (0.75°C) per 1000 ft (304.8m)  
Nonoperating 
50 to 109.4°F (10 to 43°C) 
Temperature range 
Shipment 
-104 to 140°F (-40 to 60°C) 
                                                 
1
 Maximum measured values were determined with 77°F  (25°C) ambient temperature, and your results may va ry. Idle power: 
Power drawn with the machine(s) logged into the OS, and no other applications running. Memory, HDDs, optical drives, and tape 
drives are not being used. Measured maximum power: Maximum measured power is the power drawn by the machine with the 
CPUs 100-percent used and memory is used 10 percent more than base usage. The exerciser used is Prime95 (torture test); you 
can download it at 
http://www.mersenne.org
 Rated system maximum: The maximum power the machine can draw according to the 
system label rating.