Chapter 5    Web GUI Setup and Monitoring  
 
 
 
234 
OL-31980-01 
4  From the  Enable/Disable drop-down  list, choose  Yes and the warning  message 
will be reported.  Choose No and the warning  is disabled and the Relay and Trap 
settings are ignored. 
Note: The Enable/Disable drop-down  list must be set to Yes for the Relay and 
Trap settings to be functional. 
5  If current warning  is enabled,  choose  Yes from the  Trap drop-down list and the 
SNMP trap message will be sent when  the warning  is set or cleared. 
Note: No is a read only  value that indicates the setting is Yes, but is currently 
being  suppressed because the warning  is disabled (Enb is set to No). 
6  If current warning  is enabled,  set Relay to Yes for the rear panel alarm relay  to 
be triggered  when  the warning  is set or cleared. 
Note: No is a read only  value that indicates the setting is Yes, but is currently 
being  suppressed because the warning  is disabled (Enb is set to No). 
7  Click Apply