Setup Menu 
 
 
125 
 
Menu  Item 
Description 
Parameters 
Signal Lock  Timer 
Select  the time, in seconds,  the unit  must 
wait  for  a signal lock before  declaring  that 
the signal is not  usable and move  on to  the 
next search  location  in the search  path.  The 
default  is 30 seconds. 
5 to 255  seconds 
Verify  Timer 
Select  the time, in seconds,  the unit  must 
wait  for  the PAT table to  verify the signal 
has a valid transport.  The default  is 60 
seconds. 
10 to  255 seconds 
 
 
Backup Channel 
Menu  Item 
Description 
Parameters 
PE # 
The Program  Entry (PE)  number you  are 
configuring  the backup transport  channel. 
The transcoder  supports  eight program 
entries  (PE1  to PE8).  PE1 is the decode 
channel  and is available at the analog 
outputs.  PE2 to  PE8 are available for  the 
transcoded  channels  on the ASI  and MPEG 
over IP  outputs. 
PE1 to  PE8 
Transport 
The backup  transport  number you are 
configuring  the backup channel. 
1, 2, or 3 
Backup  Channel 
The backup  channel number for  the 
selected  backup  transport. 
– 
Note: We recommend  that  you configure  a minimum of  one backup  transport.  If no backup 
transport  is configured,  an alarm is triggered, but the unit will  not be able to  switch  to  a 
backup  transport.   
 
Backup Transport 
Menu  Item 
Description 
Parameters 
Backup 
The backup  number 
1, 2, or 3