Cisco Cisco D9804 Multiple Transport Receiver Guía De Instalación
![Cisco](https://files.manualsbrain.com/attachments/7380d0050044647c30f5c24bbbf5d0c0b6d9bb84/common/fit/150/50/faa183d287233c52228cfea3dbc2a127fe780f60564fcb0955d9c3d1cd23/brand_logo.png)
Messages
78-4042990-01 Rev B
145
Message
Set/Clear Message
Cause/Remedy
Relay
Fan Failure
Fan Failure Alarm
Cause: One or more fans have failed.
Remedy: Call Cisco to return the unit for
repair.
repair.
7
SMI Setup
Phase lock error on
SMI SDRAM
SMI SDRAM
Cause: Memory timing problem.
Remedy: Call Cisco customer support.
7
BOOT
KB not accessible,
LCD not connected,
FLASH Not Found,
EMI SDRAM Test
Failed,
Failed,
BOOT Invalid, or
FPGA Invalid
Cause: A hardware problem was
detected during startup.
detected during startup.
Remedy: Reboot the MTR to attempt to
clear the problem. If the problem
persists, call Cisco Customer Support.
clear the problem. If the problem
persists, call Cisco Customer Support.
7
FPGA
Download
Failure
Download
Failure
Invalid PCB version
/ no FPGA download
support,
/ no FPGA download
support,
FPGA Init failed to go
high,
high,
FPGA Init and Done
failed to go low,
failed to go low,
FPGA Init went LOW
(CRC error),
(CRC error),
FPGA Done failed to
go high,
go high,
Invalid FPGA data,
or
or
Invalid PCB version
Cause: Fault with the FPGA. As a result,
there will be no ASI output.
there will be no ASI output.
Remedy: Reboot the unit to attempt to
clear the problem. If the problem
persists, call Cisco Customer Support.
clear the problem. If the problem
persists, call Cisco Customer Support.
7
DB NVS
DB NVS flushing
ignored,
ignored,
RAM flush to NVS
failed, or
failed, or
DVB Factory Reset
failed
failed
Cause: Failure to update non-volatile
memory.
memory.
Remedy: Reboot the unit to attempt to
clear the problem. If the problem
persists, call Cisco Customer Support.
clear the problem. If the problem
persists, call Cisco Customer Support.
7
DB NVS
DB Factory Reset in
progress
progress
Cause: The D9804 MTR is performing a
reset of settings back to the factory set
default values.
reset of settings back to the factory set
default values.
Remedy: The message will be cleared
after the factory reset.
after the factory reset.
7