Cisco 1GHz Surge-Gap Taps, Standard & Full Profile Guía De Instalación
![Cisco](https://files.manualsbrain.com/attachments/7380d0050044647c30f5c24bbbf5d0c0b6d9bb84/common/fit/150/50/faa183d287233c52228cfea3dbc2a127fe780f60564fcb0955d9c3d1cd23/brand_logo.png)
Tools and Torque Specifications
4013399 Rev C
17
Part
Torque Specification
KS-connector
Tighten according to manufacturer‟s
recommended torque specification, typically 15
ft-lb to 25 ft-lb (20.3 Nm to 33.9 Nm), but not to
exceed 60 ft-lb (81.3 Nm)
recommended torque specification, typically 15
ft-lb to 25 ft-lb (20.3 Nm to 33.9 Nm), but not to
exceed 60 ft-lb (81.3 Nm)
Port end plug
50 in-lb to 60 in-lb (5.6 Nm to 6.8 Nm)
Seizure screw
15 in-lb to 20 in-lb (1.7 Nm to 2.3 Nm)
Faceplate bolt
50 in-lb to 60 in-lb (5.6 Nm to 6.8 Nm)
F-connector (drop cable)
RG–6 or RG–59
Tighten to manufacturer‟s recommended
torque specification
torque specification
Installations involving a twisted-pair PDU also require tightening the PDU cover
screw to 50 to 60 in-lb (5.6 to 6.8 Nm).
screw to 50 to 60 in-lb (5.6 to 6.8 Nm).
Torque Sequence
The following diagrams show the proper torque sequence for closing the housing.
2/4-Way Standard Tap
8-Way Full Profile Tap