Removing and Replacing Modules 
OL-29643-02 
145 
 
 
 
4  Reattach the fiber connector to the module cover and close the cover. 
 
Forward/Reverse Configuration Module, Equalizer, and Node Signal 
Director Replacement Procedure 
The forward and reverse configuration modules, equalizers, and node signal 
directors plug into the RF amplifier assembly through cut-outs in its cover. 
To remove these modules, pull up carefully on their integrated handles until they 
separate from the RF amplifier assembly. 
 
RF Amplifier Assembly Replacement Procedure 
Follow this procedure to remove and replace the RF amplifier assembly. 
1  Open the housing. See Opening and Closing the Housing (on page 136). 
2  Remove the AC power shunts and make a note of their location for reinstallation 
in the replacement RF amplifier assembly. 
 
 
CAUTION: 
Damage to the node may result if AC power shunts are not removed 
before replacing the RF amplifier assembly.
 
 
3  Loosen the seven shoulder screws securing the RF amplifier assembly to the 
housing.