Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Guía De Instalación
Chapter 3 Configuration
28
4024769 Rev A
Menu Item Configuration Parameter Description/Values
9
9
MASTER RESET
Description: Reset configuration parameters to
their defaults.
their defaults.
Values: No, Yes
Configuring the SM
The SM can be configured using two different methods, as follows:
Auto-registering at power up
Manually assisted configuration/registering
The following sections describe these procedures in detail.
Configuring the SM Using the Auto-registering Feature
The SM transponder module is designed to work without manual configuration.
Once powered up in a network, the transponder scans for a downstream
transmission, locks in, receives commands, and then transmits its replies back to the
headend.
Once powered up in a network, the transponder scans for a downstream
transmission, locks in, receives commands, and then transmits its replies back to the
headend.
This "auto-registering" process can take up to 24 hours via HMS standards, though
one-half to two hours is more common. Once registered, the transponder does not
have to go through the process again should power be lost and then restored.
one-half to two hours is more common. Once registered, the transponder does not
have to go through the process again should power be lost and then restored.
Manually Assisting SM Configuration/Registration Using the Model 91200 Handheld
Programming Terminal
The transponder registration process can be greatly accelerated by telling the
transponder what the downstream frequency is.
transponder what the downstream frequency is.
Note: This procedure is recommended when the transponder is installed in a system
that is not fully HMS compliant. An example is using Tollgrade Cheetah Net
monitoring software with legacy transponders.
that is not fully HMS compliant. An example is using Tollgrade Cheetah Net
monitoring software with legacy transponders.
Complete the following steps to manually assist SM configuration using the
handheld terminal.
1 Connect the Model 91200 Handheld Programming Terminal to the local control
handheld terminal.
1 Connect the Model 91200 Handheld Programming Terminal to the local control
port on the SM as shown in the following illustration.