Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Guía De Instalación

Descargar
Página de 74
 
 Status Monitor Configuration Procedure
4015678 Rev B 
27
 
Menu Item  Configuration Parameter Description/Values 
RX FREQUENCY 
Description:  The downstream frequency on 
which the transponder receives commands from 
the headend. 
 
Value:  xxx.xx MHz 
 
TX FREQUENCY 
Description:  The upstream frequency on which 
the transponder transmits to the headend. 
 
Value:  xxx.xx MHz 
 
FREQUENCY SCAN 
Description:  Set transponder to auto-scan for 
communications frequency with the headend. 
 
Values:  Yes, No 
 
TX LEVEL 
Description:  The transponder's transmitting 
output power level. 
Values:  Valid range is 24 dBmV to 50 dBmV 
 
RX LEVEL 
Description:  The transponder's receive power 
level. 
Values:  Operational range is -20 dBmV to +20 
dBmV  (Anything over +30 dBmV can cause 
equipment damage.) 
 
STATUS 
Description:  Transponder module status. 
 
Values:  No Freq Found, Registered 
 
MASTER RESET 
Description:  Reset configuration parameters to 
their defaults. 
 
Values:  No, Yes