Cisco Headend System Release 2.7 Guía De Instalación
Configure OIT Bridges
4017650 Rev C
67
g In the Dncs ASI Pid column, click in the Fast Refresh EMM field and type
the hexadecimal PID value for the Fast Refresh EMM stream.
h In the Dncs ASI Pid column, click in the System Messages field and type the
hexadecimal PID value for the System Messages stream.
i In the Dncs ASI Pid column, click in the CAT field and type the hexadecimal
PID value for the CAT stream.
j In the Dncs ASI Pid column, click in the Messaging field and type the
hexadecimal PID value for the Messaging stream.
k In the Max Data Rate column, click in the EMM field and type the maximum
data rate for this stream in megabits per second (Mbps). Allowable
values=0.01-1.0 Mbps.
values=0.01-1.0 Mbps.
l In the Max Data Rate column, click in the Fast Refresh EMM field and type
the maximum data rate for this stream in megabits per second (Mbps).
Allowable values=0.51-3.0 Mbps.
Allowable values=0.51-3.0 Mbps.
m In the Max Data Rate column, click in the System Messages field and type
the maximum data rate for this stream in megabits per second (Mbps).
Allowable values=0.01-3.0 Mbps.
Allowable values=0.01-3.0 Mbps.
n In the Max Data Rate column, click in the CAT field and type the maximum
data rate for the CAT stream in megabits per second (Mbps). Allowable
values=0.01-1.0 Mbps.
values=0.01-1.0 Mbps.
o In the Max Data Rate column, click in the Messaging field and and type the
maximum data rate for this stream in Mbps. Allowable values=0.01–1.0
Mbps.
Mbps.
13 Click OK. The OIT Data Configuration window closes.
14 Click Save on the Set Up CMTS/OIT Bridge window. Your OIT Bridge
14 Click Save on the Set Up CMTS/OIT Bridge window. Your OIT Bridge
Configuration settings are saved.
Important:
Important:
After you save your OIT Data Configuration settings, the Hub Name, Bridge
Name, and the OIT Bridge checkbox cannot be changed.
Name, and the OIT Bridge checkbox cannot be changed.
If you need to set up CMTS bridges, refer to the online Help.
15 After you have configured the OIT bridges, you must now use the SI-Server to
re-configure all of your D96xx re-multiplexers (including the Home D96xx) to
pass OIT programs and PIDs.
Important: The programs 0x1FF8 and 0x1 should also be passed to the SI-Server
along with the three programs listed in items a. through c. in step 5 (EMM, Fast
Refresh EMM, and System Messages).
Note: For more information, refer to step 5 of Configuring the SI-Server, D96xx
Re-Multiplexers, and the DCM (on page 16).
pass OIT programs and PIDs.
Important: The programs 0x1FF8 and 0x1 should also be passed to the SI-Server
along with the three programs listed in items a. through c. in step 5 (EMM, Fast
Refresh EMM, and System Messages).
Note: For more information, refer to step 5 of Configuring the SI-Server, D96xx
Re-Multiplexers, and the DCM (on page 16).