Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Guía De Instalación

Descargar
Página de 16
OL-29941-01 
 
 
 
Initial Steps 
 
Input-to-Output Signal Routing by FCM 
 
FCM 
Configuration 
Part Number 
on Module 
 
Input Receiver Ports 
Output Ports 
2/3 
5/6 
1x4 
4019273 
 
 
 
1x4 w/Injection  4022272 
 
 
 
1x4 Redundant  4019275 
 
 
 
2x4 Redundant  4019279 
 
 
2x4 
4019277 
 
 
3x4 (Rx 1,3,4) 
4024784 
 
3x4 (Rx 1,2,4) 
4024786 
 
4x4 
4019281 
In this table, the letters W, X, Y, and Z identity the possible input-to-output routing 
from each receiver input port to each RF output port. 
For example, if FCM part number 4024784 is installed: 
 
Signal applied to input port 1 (X) appears at two output ports: port 4 and either 
port 5 or 6, depending on which directional splitter is installed. 
 
Signal applied to input port 3 (W) appears at output port 1 only. 
 
Signal applied to input port 4 (Y) appears at either output port 2 or output port 3, 
depending on which directional splitter is installed. 
By combining this information with visual inspection of the splitter(s) installed in 
the amplifier, you can determine where a test signal should appear as output when 
applied to each receiver input port. 
Complete the Signal Path Table 
Use the information provided above to list the corresponding output port number(s) 
for each receiver input port in the following table. 
Signal Path Table 
 
Rx Input Port 
RF Output Port(s) 
 
 
 
 
You will refer to this information when verifying correct operation following the 
upgrade.