Cisco Headend System Release 2.7 Guía Del Usuario
SDV System Communications Alarms
4022446 Rev B
29
SDV System Communications Alarms
SDV Server Trap 1 (1 Hex)
Alarm Summary:
SDV Server Unable to Communicate with DNCS SRM
Description:
This alarm occurs when the resource manager of the SDV server failed to acquire
bandwidth from the DNCS SRM.
bandwidth from the DNCS SRM.
Severity:
Major
Service Impact:
An initializing SDV SRM cannot acquire bandwidth for SDV programs.
SDV servers already running cannot acquire additional bandwidth as needed.
Check and Correct:
Possible Causes
Check and Correct Instructions
The DNCS is not responding.
The DNCS SRM is not responding.
There is a possible network problem
between the SDV server and the
DNCS.
between the SDV server and the
DNCS.
A VASP entry for the SDV server is not
entered into the DNCS database.
entered into the DNCS database.
Investigate and troubleshoot your
network, as this issue could be network-
related. Contact Cisco Services for
further assistance.
network, as this issue could be network-
related. Contact Cisco Services for
further assistance.
Verify that the correct VASP ID is
entered for the SDV server.
entered for the SDV server.
Note: In rare cases, you may see
toggling between the primary and
backup SDV servers. This condition
should be resolved within approximately
1 minute.
toggling between the primary and
backup SDV servers. This condition
should be resolved within approximately
1 minute.