RF Status Diagnostic Screen 
78-4001708-01 Rev B 
31 
 
Field 
Name 
Description 
Possible Values 
DAVIC 
The status of the current Digital 
Audio Visual Council (DAVIC) 
connection 
 
Booting—DHCT is attempting to 
initiate a DAVIC connection 
 
Calib Power—DHCT is calibrating 
the power level of the QPSK 
transmitter for optimal performance 
 
Completion—DHCT received sign 
on request; waiting for DAVIC 
initialization to complete or for 
DAVIC ranging/ power calibration 
message 
 
Conn Confirm—DHCT received a 
DAVIC connect message for a 
connection set up by an active 
session, sent a DAVIC connect 
response message, and is waiting 
for a DAVIC connect confirm 
message to acknowledge the 
session connection is ready to use 
 
Connected—connection exists; 
typically two-way 
 
Data Lock Lost—DHCT stopped 
receiving valid data; must re-
establish a DAVIC connection 
when it finds valid data 
 
Dflt Cfg—DHCT is waiting for 
DAVIC default configuration 
message 
 
DNCS Conn—DHCT adjusted its 
power, received initialization 
completion message, and is 
waiting for DNCS to send a DAVIC 
connect message to establish 
default DNCS connection