• Close the ejector levers and tighten the captive screws.
Step 5
Verify that the SFP modules are properly seated in the ports on the faceplate:
• Verify that no cables are broken at the connector.
• Verify that the transmission (Tx) and reception (Rx) are properly oriented and inserted in any optical
SFPs.
• Verify that the correct level of software licensing is available for the card.
Verifying the Status of the Line Card
Procedure
Step 1
Ensure that the STATUS LED illuminates green (module operational).
Step 2
When the Cisco RFGW-10 DS-384 is online, use the show module command to verify that the system
acknowledges the new module and that the status of the module status is good.
Step 3
If the module is not operational, re-seat it. If the module is still not operational, contact your customer service
representative.
Verifying the Status of the Supervisor Card
For installation instruction for the Supervisor card, see
.
Procedure
Step 1
Ensure that the STATUS LED illuminates green (module operational).
Step 2
When the Supervisor card is online, enter the show module all command. Verify that the system acknowledges
the new module and that the status of the module is good.
Step 3
If the module is not operational, reseat it. If the module is still not operational, contact your customer service
representative.