Cisco Cisco StadiumVision Mobile Manual De Mantenimiento

Descargar
Página de 103
 
 
© 2011 Cisco Systems, Inc. All rights reserved.   
 
Page 30 of 103 
Figure 25. 
IR for TV Control (DMP 4305G) 
 
IR Remote Sensor and IR Extender 
If the DMP is mounted behind the TV such that the IR sensor is not visible for IR 
remote control then the included IR extender may be used to extend IR control. The 
IR remote is an important troubleshooting tool so it is important to ensure that all 
DMPs can be IR controlled even if this is not needed during normal operation. 
DMP and TV Location 
Introducing Locations 
There are three object types that are used in Cisco StadiumVision Director to track 
and create relationships between DMPs and their physical location. These object 
types are as follows: 
  DMP – This object type describes a DMP with the following information. 
o
  Name – This is the name that describes the DMP. Typically it’s name derived 
from the MAC address (e.g., Unassigned-00-0f-44-01-a5-ec) or the Location 
Name. 
o
  Description – Optional field for additional description information 
o
  IP Address – DMP IP Address 
o
  MAC Address – DMP MAC Address 
  Location – This object type defines the physical location where the DMP is 
located with the following information. 
o
  Name – This is the name used to identify the location and is derived from a 
naming convention that an operator can easily identify where the DMP is 
physically located. 
o
  Description – Optional field for additional description information 
o
  Location ID – Optional field for additional location information. Typically this 
would be where blueprint location IDs would be inserted. This information is 
not always user-friendly for easy location identification. 
o
  Display Spec – Drop-down menu for choosing the TV Type at the location 
  DMP+Location – This object type is the summation of the two above objects 
when linked.