Cisco Cisco 1 GHz GainMaker Amplifier Hoja De Datos

Descargar
Página de 6
 
 
© 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 5 of 6 
6.  Reverse gain and noise figure for station with 0 dB reverse input pad, 0 dB reverse output EQ, and 1 dB 
output pad. 
7.  Reverse operational gain, noise figure, and return loss are specified without reverse switch option. If switch is 
installed, reduce gain by 0.5 dB, increase noise figure by 0.5 dB, and decrease return loss by 1 dB. 
8.  Composite intermodulation noise is a broadband noise like distortion product associated with QAM loading. 
9.  Distortion performance at reference output levels and tilt. Contact Cisco Engineering for CIN calculation. 
Table 6. 
Environmental and Mechanical Specifications 
Environmental 
Operating temperature range 
-40 to 140
°
F (-40 to 60
°
C) 
Mechanical 
Housing dimensions (LxHxD) 
17.3 in. x 7.2 in. x 7.8 in. 
439.4 mm x 182.9 mm x 198.1 mm  
Weight 
●  Housing with power supply 
●  Module 
 
12 lb 5 oz. (5.6 kg) 
5 lb 5 oz. (2.4 kg) 
Ordering Information 
The GainMaker Ordering Matrix provides ordering information for configured amplifier modules or stations. This 
section contains ordering information for required and optional accessories that are not included as part of a 
configured amplifier module or station. Consult your account representative or customer service representative for 
ordering assistance. 
The required accessories listed in Table 7 must be ordered separately (they are not included via the GainMaker 
Ordering Matrix). 
Table 7. 
Required Accessories 
Required Accessories 
Part Number 
Plug-in pads (attenuators): Available in 0.5 dB steps from 0 to 20.5 dB 
●  1 required for forward input  
●  1 required for AGC, if applicable
*
 
●  4 required for reverse (3 input, 1 output) 
*
 To determine AGC pad value, subtract 34 dB from the design value main port RF output 
level at the AGC pilot frequency. 
589693 (0 dB) sequentially through 589734 (20.5 dB) 
Plug-in forward cable equalizer: Available in 1.5 dB steps from 0 to 30 dB at 1002 
MHz  
●  1 required for forward input  
4007228 (0 dB) 
sequentially through 4007248 (30 dB) 
Plug-in reverse cable equalizer: Available in 1 dB steps from 0 to 12 dB at 40 MHz 
●  1 required for reverse output, unless design value is 0 dB (0 dB EQ is provided) 
712719 (0 dB) and 4036769 (1 dB) sequentially 
through 4036780 (12 dB) 
Plug-in signal director for auxiliary output: 1 required; choose from the following: 
●  Jumper 
●  2-way Splitter 
●  DC-8 Directional Coupler 
●  DC-12 Directional Coupler 
 
4008208 
4008364 
4008365 
4008366 
The following optional accessories listed in Table 8 may be ordered separately: