Upgrading Existing Housing Seizures 
 
Using a ½ in. nut driver, install the new seizure screws from the upgrade kit (part 
number 548775) in the housing. 
Do one of the following as appropriate: 
 
If the coaxial cable is connected to the housing, tighten each seizure screw from 2 
ft-lb to 5 ft-lb (2.7 Nm to 6.8 Nm). 
 
If the coaxial cable is not connected to the housing, proceed to To Connect the 
Coaxial Cable Pin Connector to the Node Housing (on page 24). 
Place the blue stickers on the outside of the housing between the ports to indicate 
that the upgrade has been completed. 
 
 
 