Cisco Cisco 1 GHz GainMaker Amplifier Guía De Instalación
Upgrading Existing Housing Seizures
3
Using a ½ in. nut driver, install the new seizure screws from the upgrade kit (part
number 548775) in the housing.
4
Do one of the following as appropriate:
If the coaxial cable is connected to the housing, tighten each seizure screw from 2
ft-lb to 5 ft-lb (2.7 Nm to 6.8 Nm).
If the coaxial cable is not connected to the housing, proceed to To Connect the
Coaxial Cable Pin Connector to the Node Housing (on page 24).
5
Place the blue stickers on the outside of the housing between the ports to indicate
that the upgrade has been completed.
OL-31155-01
17