Chapter 2    Installation and Configuration 
 
 
 
 
Signal Flow from Right to Left 
 
Note: Coax In may be switched with the Coax Out if you reverse the amplifier 
module and feed the signal from right to left. 
Using a ½-inch torque wrench, tighten the strand clamp bolts from 5 ft-lb to 8 ft-lb 
(6.8 Nm to 10.8 Nm). Make sure there is good mechanical contact between the strand 
and the housing. 
Note: A slight tilt of the face of the housing is normal. Cable tension will cause the 
housing to hang more closely to vertical. 
Connect the coaxial cable to the pin connector according to connector manufacturer 
specifications. 
Proceed to Installing Accessories (on page 28). 
 
To Install the Housing in a Pedestal 
Complete the following steps to install the node in a pedestal. 
Remove the cover of the pedestal. 
Remove the self-tapping bolts from the strand clamps and set the bolts and strand 
clamps aside. 
Position the housing in the pedestal frame as shown in the following illustration. 
Line up the self-tapping bolt holes on the bottom of the housing with the mounting 
holes on the bracket. 
 
26 