Cisco Cisco 1 GHz GainMaker Amplifier Guía De Instalación

Descargar
Página de 132
 
Balancing the Forward Path 
 
Determine the outside temperature at the amplifier location. 
Refer to the Manual Backoff Chart to find the proper manual backoff level for the 
current temperature and reference frequency. 
Turn the MANUAL BACKOFF potentiometer clockwise to reduce the output level 
by the amount specified in the Manual Backoff Chart. 
Note: After making this adjustment, do not adjust the MANUAL BACKOFF 
potentiometer again. 
Proceed to the next section, To Determine the Output Tilt
 
Manual Backoff Chart 
The following table displays the manual backoff level for selected frequencies and 
various temperatures. 
 
Temperature 
445.25 MHz 
Backoff level 
547.25 MHz 
Backoff level 
870 MHz 
Backoff level 
1 GHz 
Backoff level 
60°C 
140°F 
0.0 dB 
0.0 dB 
0.0 dB 
0.0 dB 
55°C 
131°F 
0.4 dB 
0.4 dB 
0.5 dB 
0.6 dB 
50°C 
122°F 
.7 dB 
0.8 dB 
1.1 dB 
1.2 dB 
45°C 
113°F 
1.1 dB 
1.2 dB 
1.6 dB 
1.7 dB 
40°C 
104°F 
1.4 dB 
1.5 dB 
2.1 dB 
2.3 dB 
35°C 
95°F 
1.8 dB 
1.9 dB 
2.7 dB 
2.9 dB 
30°C 
86°F 
2.1 dB 
2.3 dB 
3.1 dB 
3.5 dB 
25°C 
77°F 
2.5 dB 
2.7 dB 
3.7 dB 
4.0 dB 
 
OL-31155-01 