Cisco Cisco 1 GHz GainMaker Amplifier Guía De Instalación

Descargar
Página de 124
 
Chapter 4    Troubleshooting 
 
 
 
78 
 
Possible cause 
Solution 
No AC at the housing seizure. 
 
Check the AC source. 
 
Check the AC shunt power director 
configuration at the amplifier feeding AC to 
this amplifier. 
Note: Also verify the AC shunt power director 
configuration for AC output at this amplifier. 
 
Make sure that the housing seizure is properly 
tightened. 
AC at the housing seizure but not at 
the AC shunt power director. 
 
Check and/or replace the AC shunt power 
director. 
 
Check and/or replace the amplifier module. 
AC at the AC shunt power director 
but not at the amplifier test point. 
 
Check and/or replace the AC shunt power 
director. 
 
Check and/or replace the amplifier module. 
AC at the amplifier test point but not 
at the power supply test point. 
 
Check and/or replace the power supply wiring 
harness. 
 
Check and/or replace the power supply.