Chapter 2        Installation and Configuration 
 
 
 
38 
 
Removing and Installing AC Shunt Power 
Directors 
The line extenders draw AC power from the coaxial cable. This AC power comes 
from an external AC power supply. 
   
WARNING: 
When AC is applied from RF ports to units downstream, the downstream 
equipment shall also be located in a restricted access location (access restricted 
to service personnel).
 
Power can come from the input or output ports, and each line extender can pass or 
block AC power flow on any port without affecting RF continuity. However, at least 
one port must pass AC power to bring power into the line extender. 
To set the power direction, install AC shunt power directors for the ports through 
which you wish to pass AC. 
Note: A red AC shunt power director is included with the unit. The red shunt is 
used to activate the port that supplies power. The red shunt should be removed 
before installing or removing the line extender module from the housing. 
 
CAUTION: 
RF connectors and housing seizure assemblies can be damaged if AC shunt 
power directors are not removed from the line extender before installing or 
removing the line extender module from the housing.
 
 
To Remove and Install AC Shunt Power Directors 
Complete the following steps to remove and install AC shunt power directors. 
1  Open the housing. Refer to To Open the Line Extender Housing (on page 15). 
2  To remove a power director, pull it straight out from the line extender module.