Cisco Cisco 1 GHz GainMaker Amplifier Guía De Instalación

Descargar
Página de 132
 
 
Balancing the Forward Path 
 
69 
 
 
If the output tilt is more than design tilt, replace the forward input EQ with a 
lower value. 
 
If the output tilt is less than design tilt, replace the forward input EQ with a 
higher value. 
3  Measure the output tilt again, and then return to step 1. 
 
To Set the Output Level 
After setting the tilt, complete the following steps to select the proper pad values for 
the line extender. The output level of the line extender is set by selecting the proper 
pad value. 
1  Connect the test probe to the forward main output test point. 
2  Measure the output level at the highest design frequency, and compare this level 
with the design level (on the design print). 
3  Is the measured output level within ±0.5 dB of the design level? 
 
If the output level is within ±0.5 dB of the design output level, proceed to 
step 5. 
 
If the output level is more than the design output level, replace the forward 
input pad with a higher value pad. 
 
If the output level is less than the design level, replace the forward input pad 
with a lower value pad. 
4  Repeat steps 2 and 3 until the output level is correct. 
5  Proceed to Balancing the Reverse Path (on page 77). 
 
Forward Path Balancing for Thermal Stations Using Line Extender and 
Coax Compensation Mode 
Before you begin, make sure that you have configured the line extender module 
according to the specifications in the design print, and that the line extender has 
warmed up for approximately one hour. 
Note: If it is necessary to balance a thermal station using line extender and coax 
compensation mode immediately after module installation (with little or no 
warm-up period), the output level should be set 1 dB lower than specified by the 
design print. This reduction in output level will be offset by an increase in internal 
line extender gain as the thermal circuit in the line extender warms up. 
 
To Set Switch S1 for Line Extender and Coax Compensation Mode 
You must set switch S1 to position number 3 to use line extender and coax 
compensation mode.