GainMaker Amplifier Reverse Switch Removal Instruction Sheet 
748052 Rev C 
Line Extender Reverse Switch Removal,
 Continued 
Closing the Line Extender Housing 
Follow these steps to close the line extender housing. 
 
1. 
Inspect the housing gasket and all mating surfaces.  Wipe off any dirt and 
debris. 
 
  CAUTION: 
Avoid moisture damage and RF leakage!  Follow steps 2 and 3 
exactly as 
explained below to ensure a proper seal. 
2. 
Close the housing and finger-tighten all closure bolts. 
3. 
Using a torque wrench, tighten each closure bolt from 5 ft-lb to 12 ft-lb (6.8 
Nm to 16.3 Nm). 
Important:  Follow the numbered sequence shown below to tighten the bolts. 
 
4. 
Is the line extender located in the field? 
• 
If Yes, the reverse switch removal procedure is complete. 
• 
If No, proceed to Re-Boxing the Line Extender. 
Re-Boxing the Line Extender 
Follow these steps to re-box the line extender. 
 
1. 
Put the line extender back into its original box, then seal the box. 
2. 
Place the new 3”x 2” label over the original label on the side of the box.