Cisco Cisco 1 GHz GainStar Amplifier Guía De Instalación
Installation and Configuration
17
Installing the Housing
To Install the Housing on a Strand (Aerial)
Complete the following steps to install the housing on a strand (aerial). The housing
does not need to be opened for strand installation.
Important: The minimum strand diameter should be 5/16 inch.
does not need to be opened for strand installation.
Important: The minimum strand diameter should be 5/16 inch.
CAUTION:
Be aware of the size and weight of the housing while strand
mounting. Ensure that the strand can safely support the weight of
the housing.
mounting. Ensure that the strand can safely support the weight of
the housing.
1 Loosen the strand clamp bolts.
2 Lift the housing to the proper position on the strand.
3 Slip the strand clamps over the strand and finger-tighten the clamp bolts. This
2 Lift the housing to the proper position on the strand.
3 Slip the strand clamps over the strand and finger-tighten the clamp bolts. This
allows additional movement of the housing as needed.
4 Move the housing as needed to install the coaxial cable and connectors. See the
diagram below.
5 Using a ½-inch torque wrench, tighten the strand clamp bolts from 6.8 Nm to 9.0
Nm. Make sure there is good mechanical contact between the strand and the
housing.
Note: A slight tilt of the housing face is normal. Cable tension will cause the
housing to hang more closely to vertical.
housing.
Note: A slight tilt of the housing face is normal. Cable tension will cause the
housing to hang more closely to vertical.
6 Connect the coaxial cable to the pin connector according to connector
manufacturer specifications.
7 Proceed to Installing the Accessories.