Important Safety Instructions 
xiv 
 
 
Class II Mains Powered Equipment – Provided with a 2-terminal AC inlet that 
may be connected by a 2-terminal power cord to the mains supply outlet. No 
connection to the protective ground is required as this class of equipment is 
provided with double or reinforced and/or supplementary insulation in 
addition to the basic insulation provided in Class I equipment.   
Note: Class II equipment, which is subject to EN 50083-1, is provided with a 
chassis mounted equipotential bonding terminal. See the section titled 
Equipotential Bonding for connection instructions.   
 
Equipotential Bonding 
If this equipment is equipped with an external chassis terminal marked with the IEC 
60417-5020 chassis icon (
), the installer should refer to CENELEC standard EN 
50083-1 or IEC standard IEC 60728-11 for correct equipotential bonding connection 
instructions. 
 
AC Power 
Important: If this equipment is a Class I equipment, it must be grounded. 
 
If this equipment plugs into an outlet, the outlet must be near this equipment, 
and must be easily accessible. 
 
Connect this equipment only to the power sources that are identified on the 
equipment-rating label normally located close to the power inlet connector(s). 
 
This equipment may have two power sources. Be sure to disconnect all power 
sources before working on this equipment. 
 
If this equipment does not have a main power switch, the power cord connector 
serves as the disconnect device. 
 
Always pull on the plug or the connector to disconnect a cable. Never pull on the 
cable itself. 
 
Unplug this equipment when unused for long periods of time. 
 
Connection to -48 V DC/-60 V DC Power Sources 
If this equipment is DC-powered, refer to the specific installation instructions in this 
manual or in companion manuals in this series for information on connecting this 
equipment to nominal -48 V DC/-60 V DC power sources.