Cisco Cisco Prisma II EDR Receiver Guía De Instalación
78-713378-01 Rev C
Operation Using the ICIM
3-21
Checking Reverse Receiver Alarms Using the ICIM,
Continued
Module Alarm Data Display
The module alarm data for this module is shown below. For additional
troubleshooting information, see Chapter 5, Maintenance and Troubleshooting.
Alarm
Function
Major
Low
Limit
Minor
Low
Limit
Minor
High
Limit
Major
High
Limit
Operating
Range
InPwr1Mx Maximum optical
input power limit
-100
-100
3.2
3.2
N/A
InPwr2Mx Maximum optical
input power limit
-100
-100
3.2
3.2
N/A
PsOk
Bus voltage status
N/A
N/A
N/A
N/A
OK
Alarm1
Manual (forced)
alarm
N/A
N/A
N/A
N/A
N/A
Alarm2
Manual (forced)
alarm
N/A
N/A
N/A
N/A
N/A
Module Alarm Menus
After
the module’s ALARM function is selected, press the
key or the
key
to scroll through active alarms. Some typical module ALARMS screens are shown
below.
A L A R M S
- - - - - - - - - -
S h e l f 5
S l o t 1 6
- - - - - - - - - -
R e v e r s e
D a t a
R e c e i v e r
- - - - - - - - - -
I n P w r 1 M x
M a j L
I n P w r 2 M x
M a j L
▲ ▼
A L A R M S
- - - - - - - - - -
S h e l f 5
S l o t 1 6
- - - - - - - - - -
R e v e r s e
D a t a
R e c e i v e r
- - - - - - - - - -
P s O k
M a j L
▲ ▼
A L A R M S
- - - - - - - - - -
S h e l f 5
S l o t 1 6
- - - - - - - - - -
R e v e r s e
D a t a
R e c e i v e r
- - - - - - - - - -
A l a r m 1
A l a r m 2
▲ ▼