Cisco Prisma II 1310 nm HDTx Transmitters Guía De Instalación

Descargar
Página de 139
78-748705-01 Rev C 
Maintenance and Troubleshooting 
5-5 
Troubleshoot Alarm Conditions,
 Continued 
 
Alarm  
Alarm Condition 
Indication 
Possible Cause 
Las1Temp 
Laser 1 temperature 
is out of spec.   
Fault 
Ensure transmitter is 
within temperature specs 
and laser has had a chance 
to stabilize. 
FPGA2 
Indicates that 
FPGA2 can be read 
and written to. 
Fault 
Hardware failure. 
Clock2 
Alarms when the 
100 MHz or 125 
MHz clock has lost 
lock in transmitter 2. 
Fault 
Check Clk100_2 and 
Clk125_2 monitors to see 
which clock is lost.  Ensure 
module Clk_Src has not 
been accidentally set to 
Slave.  If in Slave mode, 
make sure there is a valid 1 
MHz reference present. 
Las2Pres 
Transmitter 2 is 
missing.   
Fault 
Ensure transmitter 2 is 
installed and fully seated. 
Las2EOL 
Laser 2 is near end 
of life.   
Fault 
Time to replace 
transmitter 2. 
Las2Temp 
Laser 2 temperature 
is out of spec.   
Fault 
Ensure transmitter 2 is 
within temperature specs 
and laser has had a chance 
to stabilize. 
LasBias1 
Bias current of the 
laser in Laser 1 is 
out of spec. 
Minor L or H  
Major L or H  
Re-seat transmitter. 
LasBias2 
Bias current of the 
laser in Laser 2 is 
out of spec. 
Fault 
Re-seat transmitter. 
ProcTemp 
Processor 
temperature. 
Minor L or H  
Major L or H  
Check fan tray operation.