Operation Using the ICIM 
78-748705-01 Rev C 
Monitor Processor Status Using the ICIM 
Introduction 
The ICIM allows you to monitor the operating status of parameters. 
STATUS Parameters 
The table below describes the monitored status parameters for this processor. 
 
Parameter  
Units 
Indication 
+1_8VInt 
Internal voltage level-nominal 1.8 V DC. 
+3_3VInt 
Internal voltage level-nominal 3.3 V DC. 
ProcTemp 
Temperature of the processor in degrees C. 
Las1Inst 
Yes or No  Indicates if transmitter 1 is installed. 
Clk100_1 
OK or 
Fault 
Indicates if transmitter 1 100 MHz clock is phase 
locked to the 1 MHz reference. 
Clk125_1 
OK or 
Fault 
Indicates if transmitter 1 125 MHz clock is phase 
locked to the 100 MHz clock.   
LasBias1 
mA 
Indicates laser 1 bias current in mA. 
Las1Temp 
delC 
Indicates laser 1 temperature in degrees C relative to 
its target temperature. 
Las1Type 
0 or 3 
Indicates type of transmitter installed. 
• 
0 = 1550 nm cooled laser transmitter 
• 
3 = Uncooled 1550 nm or 1310 nm laser 
transmitter 
Las2Inst 
Yes or No  Indicates if transmitter 2 is installed. 
Clk100_2 
OK or 
Fault 
Indicates that transmitter 2 100 MHz clock is phase 
locked to the 1 MHz reference. 
Clk125_2 
OK or 
Fault 
Indicates if transmitter 2 125 MHz clock is phase 
locked to the 100 MHz clock.   
LasBias2 
mA 
Indicates laser 2 bias current in mA. 
Las2Temp 
delC 
Indicates laser 2 temperature in degrees C relative to 
its target temperature.