Cisco Cisco MXE 3500 (Media Experience Engine) Guía Para Resolver Problemas

Descargar
Página de 3
Chassis:
    Power: on
    Serial Number: xxxxxxxxxx
    Product Name:
    PID : MXE−3500−V2−K9=
    UUID: xxxxxxxxxx
    Locator LED: off
    Description:
    Power Restore Policy: restore−last−state
    Power Delay Type: fixed
    Power Delay Value(sec): 0
MXE−3500−1 /chassis # show pci−adapter detail
Slot 6:
    Vendor ID: 0x14e4
    Device ID: 0x1639
    SubVendor ID: 0x14e4
    SubDevice ID: 0x1639
    Product Name : Broadcom 5709 1 Gbps 2−or−4 port NIC
Slot 7:
    Vendor ID: 0x1000
    Device ID: 0x0079
    SubVendor ID: 0x1000
    SubDevice ID: 0x9260
    Product Name : LSI 9260−4i MegaRAID SAS HBA
## Note the slot number the MegaRAID controller is installed in.
## This slot number is used in the next command.
MXE−3500−1 /chassis # scope storageadapter SLOT−7
MXE−3500−1 /chassis/storageadapter # show detail
PCI Slot SLOT−7:
    Info Valid: Yes
    Info Invalid Cause:
    Product Name: LSI MegaRAID SAS 9260−4i
    Serial Number: xxxxxxxxx
    Firmware Package Build: 12.12.0−0087
    Product ID: LSI Logic
Battery Status: charging
    Cache Memory Size: 0 MB
MXE−3500−1 /chassis/storageadapter # show bbu detail
Controller SLOT−7:
    Info Valid: Yes
    Info Invalid Cause:
    Battery Type: iBBBU08
Battery Present: true
    Voltage: 4.086 V
    Current: 0.000 A
    Charge: 100%
Charging State: charging
    Temperature: 32 degrees C
    Voltage Low: false
    Temperature High: false
    Learn Cycle Requested: false
    Learn Cycle Active: false
    Learn Cycle Failed: false
    Learn Cycle Timeout: false
    I2C Errors Detected: false
    Battery Replacement Required: false
    Remaining Capacity Low: false
MXE−3500−1 /chassis/storageadapter #
In the example you can see that the BBU is present, is charging, and shows a normal status.
Complete these steps if you receive an error message when you enter the show bbu detail command or if the
Battery Present state is false: