Registering CSR 1000V Licenses
If you configure Smart Licensing for a CSR 1000V edge router but the license does not automatically register with the edge router,
you must manually register the license by using the CLI as described in this procedure.
Before You Begin
• In the Prime Network Services Controller GUI, confirm that the CSR 1000V edge router is up and running.
• Obtain the token from the Smart License portal.
Procedure
Step 1
Using the CSR 1000V management IP address, open the console for the edge router and log in to the CLI.
Step 2
Confirm that the license is not registered with the edge router by entering the show license all command. The Smart
Licensing State field displays
unidentified
to indicate that no license is registered.
Step 3
Register the license with the edge router by entering the command license smart register idtoken token where token is
the token obtained from the Smart License portal.
Step 4
Wait one minute and enter the show license all command again to confirm that the license has been registered with the
edge router.
Updating Device Adapter Properties
If you enter incorrect information when deploying the Prime Network Services Controller Device Adapter, it will not be able to
register with Prime Network Services Controller. For example, if you enter the wrong IP address or shared secret password when
deploying the OVF, the Device Adapter cannot register with Prime Network Services Controller. If this occurs, use the following
procedure to correct the situation.
Procedure
Step 1
In the hypervisor, stop the Device Adapter VM.
Step 2
Navigate to the OVF settings in the hypervisor and update the properties as required.
Step 3
Restart the Device Adapter.
The Device Adapter should register with Prime Network Services Controller.
Device Adapter Not Reachable
Certain circumstances, such as loss of network connectivity, can cause Prime Network Services Controller and the Prime Network
Services Controller Device Adapter (Device Adapter) to lose communication with each other. If this occurs, use the instructions in
this topic to recover communications.
First, verify that Prime Network Services Controller and the Device Adapter cannot communicate with each other. To do this, log in
to the Prime Network Services Controller GUI and choose Administration > Service Registry. The Device Adapter should be
displayed with two entries: managed-endpoint and mgmt-controller. If both entries are in lost-visibility state, it indicates that Prime