Cisco Cisco OptoStar II Driver Amplifier Guía De Instalación

Descargar
Página de 64
General Troubleshooting Information, Continued 
Troubleshooting 
If the red alarm indicator on the front panel of the module is illuminated, check 
the OptoStar II ICIM display, the OptoStar II console, or the OptoStar II NMS for 
alarm code. See Alarm Code List (on page 3-13) to determine the cause of the 
alarm. See the table below. 
Alarm 
Possible Cause 
Servicing Instruction 
High Module 
Temperature 
 
High ambient 
temperature leading 
to insufficient heat 
dissipation 
 
Poor chassis 
ventilation 
 
Chassis fan failure 
 
Ensure good ventilation   
 
Put the chassis in a place 
with good ventilation 
 
In case of fan failure, 
repair or replace the fan, 
or contact the 
manufacturer for 
servicing 
Low or High RF 
Input Level in 
Channel A/B   
 
RF source failure   
 
RF cable or connector 
failure   
 
Make sure the RF 
connector matches   
 
Make sure the cable 
works properly 
 
Inspect if the RF input 
level meets the 
specifications 
Calibrated signal level + 
preset threshold >A/B 
channel input level > 
calibratedi signal level - 
preset threshold 
 
If the input level is 
normal, contact the 
manufacturer for 
servicing 
 
 
 
4-4 
Troubleshooting 
OL-29669-02