Alarm 
Possible Cause 
Servicing Instruction 
No RF Signal 
Output 
 
No optical output 
power in reverse 
transmitter of the 
node 
 
Splitter failure 
 
If optical input power 
and test point output 
signal meet 
specifications, but no 
signal at RF output, 
then connector failure 
at the RF output 
 
If optical input power 
meets specifications, 
but no signal at test 
point and RF output, 
then amplifier module 
failure in the reverse 
receiver   
 
Check the optical output 
power in reverse 
transmitter of the node 
 
Check splitter for optical 
signal 
 
Check whether the RF 
connectors match, and 
check for connector 
failure 
 
Measure whether the 
optical input power meets 
specifications 
 
Measure whether the test 
point output signal meets 
specifications 
 
Measure whether the 
signal strength at RF 
signal output meets 
specifications 
 
If the problem persists, 
contact the manufacturer 
for servicing 
High Module 
Temperature 
 
High ambient 
temperature lead to 
insufficient heat 
dissipation 
 
Poor chassis 
ventilation 
 
Chassis fan failure 
 
Ensure good ventilation 
 
Put the chassis in a place 
with good ventilation 
 
In case of the chassis fan 
failure, replace the fan, or 
contact the manufacturer 
for servicing 
 
CAUTION: 
Do not open the enclosure of this module in any case. Opening the enclosure 
may result in equipment damage, and you may lose the warranty eligibility. 
 
 