Specifications
Network Specifications
Interface Specifications for Rear I/O Card
Interface Specifications for Rear I/O Card
1.0 Gbps RPR*/RPT Intermediate Reach 1310 nm
− Rx Input Power (max) = -3 dBm
− Rx Input Power (max) = -3 dBm
− Rx Sensitivity Minimum (avg) = -19 dBm
− Tx Power (avg) = -11 (min) to -3 (max) dBm
2.5 Gbps RPR/RPT Intermediate Reach 1310 nm
2.5 Gbps RPR/RPT Intermediate Reach 1310 nm
− Rx Input Power (max) = 0 dBm
− Rx Sensitivity Minimum (avg) = -22 dBm
− Tx Power (avg) = -10 (min) to -3 (max) dBm
1.0 Gbps RPR/RPT Long Reach 1550 nm
1.0 Gbps RPR/RPT Long Reach 1550 nm
− Rx Input Power (max) = -3 dBm
− Rx Sensitivity Minimum (avg) = -23 dBm
− Tx Power (avg) = -3 (min) to 2 (max) dBm
2.5 Gbps RPR/RPT Long Reach 1550 nm
− Rx Input Power (max) = -7 dBm
2.5 Gbps RPR/RPT Long Reach 1550 nm
− Rx Input Power (max) = -7 dBm
− Rx Sensitivity Minimum (avg) = -30 dBm
− Tx Power (avg) = -2 (min) to 3 (max) dBm
Performance Parameters
Conforms to RFC 2863 for the Interface Group MIB
Full optical LOS monitoring capabilities
Full optical LOS monitoring capabilities
Supported Standards
Telcordia GR-1089
Physical Specifications
Connectors
Connectors
Small form factor pluggable (SFP) Optics
− 1310 Intermediate Reach, 10 km
− 1550 Long Reach, 70 km
Environmental
Operating temperature: 0° to 50°C / 32
° to 122°F
(extended operation above 40
°
C / 104
°
F not recommended)
Storage temperature: -40°C to 70°C / -40°F to 158°F
Humidity: 5% to 85% (non-condensing)
Power: Front Card - 90 Watts (max)
Rear Card - 15 Watts (max)
Humidity: 5% to 85% (non-condensing)
Power: Front Card - 90 Watts (max)
Rear Card - 15 Watts (max)
Protection
Unprotected single subtending ring configuration
Dual subtending ring configuration
Protected single subtending ring configuration
Hot swappable front and rear cards
Dual subtending ring configuration
Protected single subtending ring configuration
Hot swappable front and rear cards
Physical
Slot Width: 1 Front Card, 1 Rear I/O Card
Number of ports per card: 4 TxRx optical pairs
(1 East TxRx, 1 West TxRx, 2 Bypass TxRx pairs)
Number of ports per card: 4 TxRx optical pairs
(1 East TxRx, 1 West TxRx, 2 Bypass TxRx pairs)
Agency compliance
Safety
Safety
UL, cUL, TÜV
Emissions
FCC CLASS A, CE
*This includes a pre-standard implementation of RPR. The product cannot be claimed to be RPR-compliant, since the standard is
not yet finalized.
not yet finalized.
Scientific-Atlanta, the Scientific-Atlanta logo, and Prisma are registered trademarks of Scientific-Atlanta, Inc.
Prisma IP is a trademark of Scientific-Atlanta, Inc.
Cisco, Cisco Systems, and the Cisco Systems logo are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the
U.S. and certain other countries.
All other trademarks shown are trademarks of their respective owners.
Specifications and product availability are subject to change without notice. Not all features will be available at first product
release.
© 2006 Scientific-Atlanta, Inc. All rights reserved.
Scientific-Atlanta, Inc.
1-800-722-2009 or 770-903-6900
Prisma IP is a trademark of Scientific-Atlanta, Inc.
Cisco, Cisco Systems, and the Cisco Systems logo are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the
U.S. and certain other countries.
All other trademarks shown are trademarks of their respective owners.
Specifications and product availability are subject to change without notice. Not all features will be available at first product
release.
© 2006 Scientific-Atlanta, Inc. All rights reserved.
Scientific-Atlanta, Inc.
1-800-722-2009 or 770-903-6900
www.scientificatlanta.com
Part Number 7000888 Rev C