7   © 2016 Cisco and/or its affiliates. All rights reserved.
Table 1 lists the hardware and software components used in this deployment.
Table 1.  Hardware Software Components
Component
Description
Cisco UCS
• 1 Cisco UCS Mini chassis
• 2 Cisco UCS 6324 Fabric Interconnects with Cisco UCS Manager 3.0(2c)
• 4 Cisco UCS B200 M4 Blade Servers
 
-2 x Intel Xeon processor E5-2620 v3 CPUs per blade server
 
-8 x 16-GB DDR4 2133-MHz RDIMMs, PC4-17000, dual-rank, x4, and 1.2V per blade server
 
-2 x 1.2-TB SAS 10,000-rpm SFF HDDs per blade server
 
-1 UCSB-MRAID12G controller per blade server
 
-1 Cisco UCS VIC 1340 (UCSB-MLOM-40G-03) per blade server
 
-2 x 32-GB Cisco Flexible Flash cards (UCS-SD-32G-S) per blade server
Cisco UCS firmware
• Cisco UCS Manager Release 3.0(2c)
• Infrastructure firmware Release 3.0(2c)A 
VMware vSphere
• VMware vCenter Release 6.0.0b
• VMware ESXi Release 6.0.0b
StorMagic SvSAN
Release 5.3
Note: New Software and Firmware releases should be installed as listed in Cisco UCS HW and SW Interoperability Matrix:  
http://www.cisco.com/web/techdoc/ucs/interoperability/matrix/matrix.html
 and SvSAN certified and supported version appears 
on the VMware HCL:
 http://www.vmware.com/resources/compatibility/search.php 
Table 2 shows the virtual machine sizing assumptions used for this Cisco UCS with StorMagic SvSAN deployment. 
Table 2.  Virtual Machine Configuration
Item
Description
Virtual machine instance size
4 virtual CPUs (vCPUs) with 6 GB of RAM
50-GB OS LUN; 100-GB raw LUN for I/O test