Cisco Cisco Packet Data Interworking Function (PDIF)
Engineering Rules
HNB-GW Engineering Rules ▀
HNB-GW Administration Guide, StarOS Release 16 ▄
137
HNB-GW Engineering Rules
The following engineering rules apply when the system is configured as an HNB-GW:
A maximum of 16 HNB-GW service can be configured on a system which is further limited to a maximum of
256 services (regardless of type) can be configured per system.
A maximum of 16 CS-network instances can be configured on system for HNB-GW network function but
multiple HNB-GW services can be associated with the same CS-network instance.
A maximum of 16 PS-network instances can be configured on system for HNB-GW network function but
multiple HNB-GW services can be associated with the same PS-network instance.
A particular HNB-GW service can be associated with more than one CS/PS network entity.
A maximum of 12 HNB-SCCP-network instance can be configured on system for HNB-GW network function.
A maximum of 4 HNB-ALCAP service can be configured on system for HNB-GW network function.
A maximum of 4 Radio Network PLMN ids can be configured in an HNB-GW service.
A maximum of 1 RNC id can be configured in a Radio Network PLMN.
A maximum of 1 SeGW IP address can be associated with an HNB-GW service.