Cisco Headend Digital Broadband Delivery System Guía De Instalación
Chapter 2 SR 2.8.1/3.8.1/4.3.1 Upgrade Procedures
58
4036043 Rev B
10 Open the .profile file with a text editor.
11 Choose one of the following options:
11 Choose one of the following options:
If the SI_REGENERATION_TIME variable is not yet present in the .profile
file, append the variable to the file and set it to 1200.
file, append the variable to the file and set it to 1200.
If the SI_REGENERATION_TIME variable is present in the .profile file but
is set incorrectly, change it to 1200.
Example: When you are finished, your entry should be:
is set incorrectly, change it to 1200.
Example: When you are finished, your entry should be:
SI_REGENERATION_TIME=1200
12 Save and close the file.
Bounce the siManager Process
If you made any edits to the .profile file for the PSIP_INSERT_RATE or the
SI_REGENERATION_TIME variables, you need to bounce the siManager process
of the DNCS in order for the system to recognize those changes.
1 When completing the
SI_REGENERATION_TIME variables, you need to bounce the siManager process
of the DNCS in order for the system to recognize those changes.
1 When completing the
Verify the PSIP and SI_REGENERATION_TIME
Variables (on page 52) procedure, did you make any changes to the .profile file?
If yes, continue with step 2.
If no, skip to the next procedure in this chapter. You have no need to bounce
the siManager process.
the siManager process.
2 Log out of the DNCS.
3 Log back onto the DNCS as dncs user. The changes you made to the .profile file
3 Log back onto the DNCS as dncs user. The changes you made to the .profile file
are now available to the siManager process.
4 Follow these instructions to stop the siManager process.
a Select siManager in the DNCS Control window.
b Click Process.
c Select Stop Process.
d Wait for the indicator of the siManager process to become red.
b Click Process.
c Select Stop Process.
d Wait for the indicator of the siManager process to become red.
5 Follow these instructions to restart the siManager process.
a Select siManager in the DNCS Control window.
b Click Process.
c Select Start Process.
d Wait for the indicator of the siManager process to become green.
b Click Process.
c Select Start Process.
d Wait for the indicator of the siManager process to become green.